The Queensland Urban Utilities standards 2011 are superseded by the SEQ Water Supply & Sewerage Design & Construction Code which took effect on 1/07/2013, but are provided here for reference.

For reference only

The Water Services Association of Australia has developed a suite of Code of Practices for the design and installation of water supply and sewerage assets.

However, because of differences in regional business practices it has not been possible for Queensland Urban Utilities to implement all aspects of the National Codes. Queensland Urban Utilities' requirements that are different from the National Codes are included in Supplementary Manuals. Queensland Urban Utilities' Supplementary Manuals together with the National Codes, form the Queensland Urban Utilities Water Supply and Sewerage Reticulation Standards.

The Supplementary Manuals are available free of charge. The drawings may be printed in either A4 or A3 format.

The Water Services Association of Australia National Codes can only be purchased from Water Services Association of Australia.

If you require any of the following files, please use the enquiry form.

Queensland Urban Utilities supplementary manual to Water Services Association of Australia Sewerage Code

Amendments

Amendment No.1 (50 kb)

Amendment No.2 (77.6 kb)

Introduction (235 kb)
Part 1 – Planning and design (A3) (208 kb)
Part 1 – Planning and design (A4) (117 kb)
Part 2 – Products and materials (A3) (243 kb)
Part 3 - Construction (A3) (53 kb)
Part 3 – Construction (A4) (64 kb)
Part 4 – Standard drawings (A3) (199 kb)
Appendix SA – Queensland Urban Utilities standard drawings list (35 kb)
Appendix SB - Legend for sewerage drawings (206 kb)
Appendix SC – Authorised product list - sewerage (37 kb)

Low pressure sewers

Queensland Urban Utilities low pressure sewers (390 kb)

Nusewers

Nusewers - (Design and construction specification) (70 kb)

Queensland Urban Utilities standard drawings - sewerage

Sewerage reticulation layout, longitudinal section and live sewer details
VC, UPVC, DICL and pipeline construction details
Maintenance hole details
Property connection and overflow chamber details
MH cover, ladder, surface box and material details
Post construction, NuSewer and low pressure sewer details

Queensland Urban Utilities standard drawings - sewerage pumping station

Pumping station layout, level interaction, P&ID, pump curve and storage chamber details
Grit collector maintenance hole details
Wetwell details - part 1
Wetwell details - part 2
Aluminium access cover details
PE lining, potable water, ladders and component details

Queensland Urban Utilities supplementary manual to WSAA Water Supply Code

Amendments

Amendment No.1

Amendment No.2 (93 kb)

Introduction (187 kb)
Part 1 – Planning and design (A3) (90 kb)
Part 1 – Planning and design (A4) (91 kb)
Part 2 – Products and materials (A3) (178 kb)
Part 3 – Construction (A3) (53 kb)
Part 3 – Construction (A4) (186 kb)
Part 4 – Standard drawings (A3) (197 kb)
Appendix WA – Queensland Urban Utilities standard drawings list - water supply (28 kb)
Appendix WB – Legend for water reticulation drawings (149 kb)
Appendix WC – Fire hydrant and hose reel metering arrangements (59 kb)
Appendix WD – Authorised product list - water supply (57 kb)
Appendix WE - PE water mains specifications (37 kb)
Appendix WF - Disinfection procedure summary (53 kb)
Appendix WG - Design of private booster pump installations (26 kb)
Appendix WH - Submetering of multi-unit properties specifications (267 kb)

Dual supply water systems

Queensland Urban Utilities amendments to WSAA dual water supply systems (Introduction) (178 kb)

Queensland Urban Utilities amendments to WSAA dual water supply systems (A3) (221 kb)

Queensland Urban Utilities standard drawings - water supply

Water reticulation plan details, environmental notes and PE water mains
Valve, hydrant and scour installations and construction details
Fire hydrant marker post and pavement marker details
Water services and meter arrangement details
Surface boxes and valve spindle cap details